High-precision reading system with SQUARE-WAVE OUTPUT |
|
High-precision miniaturized reading system with SQUARE-WAVE OUTPUT |
|
High-precision reading system with SINE-WAVE OUTPUT (1 Vpp) |
|
Single-axis digital readout |
|
Digital readout with magnetic sensor . |
|
Magnetic bands for MTS, MTV and MTR sensors |
|
Stainless steel cover (CV103) for magnetic band and aluminium support (SP202) for operating machine |
|
MTS P Pole pitch 1+1 mm Pr |
|
Pole pitch |
1+1 mm |
Available resolutions |
10 - 5 - 1 - 0,5 μm |
Accuracy |
± 10 µm |
Sensor - magnetic band gap |
0,1 ÷ 0,5 (with band MP100) |
Reference signal |
at constant pitch of 1 mm (C) |
Repeatability |
± 1 increment |
Output |
LINE DRIVER / PUSH-PULL |
Power supply |
5 ÷ 28 Vdc ± 5% |
Max. frequency |
300 kHz |
Max. speed |
0,6 m/s (MTS P05) – 1,2 m/s (MTS P1) |
Protection class |
IP 67 |
Electrical protections |
inversion of polarity and short circuit |
MTS M Pole pitch 2+2 mm Pr |
|
Pole pitch |
2+2 mm |
Available resolutions |
1000 - 500 - 100 - 50 - 25 - 10 - 5 - 1 μm |
Accuracy |
± 15 µm |
Sensor - magnetic band gap |
0,3 ÷ 1,5 (with band MP200)
0,35 ÷ 0,9 (with band MP200Z) |
Reference signal |
at constant pitch of 2 mm C external E positioned on magnetic band Z |
Repeatability |
± 1 increment |
Output |
LINE DRIVER / PUSH-PULL |
Power supply |
5 ÷ 28 Vdc ± 5% |
Max. frequency |
300 kHz |
Max. speed |
1,2 m/s (MTS M1) – 12 m/s (MTS M10) |
Protection class |
IP 67 |
Electrical protections |
inversion of polarity and short circuit |
MTS H Pole pitch 5+5 mm Pr |
|
Pole pitch |
5+5 mm |
Available resolutions |
100 - 50 - 25 - 10 - 5 μm |
Accuracy |
± 40 µm |
Sensor - magnetic band gap |
0,3 ÷ 3,5 (with band MP500) |
Reference signal |
at constant pitch of 5 mm (C)
external (E) |
Repeatability |
± 1 increment |
Output |
LINE DRIVER / PUSH-PULL |
Power supply |
5 ÷ 28 Vdc ± 5% |
Max. frequency |
300 kHz |
Max. speed |
6 m/s (MTS H5) – 12 m/s (MTS H10) |
Protection class |
IP 67 |
Electrical protections |
inversion of polarity and short circuit |
|
|