GIVI
ME510
Single-axis digital readout

ME518
Single-axis digital readout, with 7-digit display

ME600
Multi-axis digital readout, without auxiliary display

ME800
Multi-axis digital readout, with auxiliary LCD display

VI700
Multi-axis digital readout, with LED display .

VI900
Multi-axis digital readout, touch screen color LCD

Supporting arms
DRO Supporting arms

▪ Up to 7 digits displayed, with floating decimal point.
▪ Resolutions up to 0.5 μm.
▪ Internal rewritable memory (no buffer battery required).
▪ Correction factor, midpoint calculation, relay output and many other functions available.
▪ Applicable on several machine-tools performing cuttings or machining at a preset size,   polishing, bending,
  grinding, straightening, etc., in several sectors such as: wood, sheet metal, marble,
  textile, rubber, etc. processing machines.


ME518   Standard version
Display
7 high-efficiency digits   h = 13 mm
Signal input
2 square waves out of phase 90° ± 5° and zero ref.
5 Vdc or 12 Vdc
Power supply
230 Vac ± 10% - 50/60 Hz 30 mA
110 Vac ± 10% - 60 Hz 60 mA
24 Vac ± 10% - 50/60 Hz 300 mA
Memory
permanent for configuration and “user” settings
(last data operating memory)
Available resolutions
100 - 50 - 20 - 10 - 5 - 2 - 1 μm
1° - 0,5° - 0,2° - 0,1° - 0,05° - 0,02° - 0,01°

ME518 UR2 – ME510 S   Version with options
 
Display
7 high-efficiency digits   h = 13 mm
Signal input
2 square waves out of phase 90° ± 5° and zero ref.
5 Vdc or 12 Vdc
Power supply
230 Vac ± 10% - 50/60 Hz 30 mA
110 Vac ± 10% - 60 Hz 60 mA
24 Vac ± 10% - 50/60 Hz 300 mA
Memory
permanent for configuration and “user” settings
(last data operating memory)
Available resolutions
100 - 50 - 20 - 10 - 5 - 2 - 1 μm
1° - 0,5° - 0,2° - 0,1° - 0,05° - 0,02° - 0,01°
Options
serial output RS-232 relay output
static relay AC - static relay DC

FUNCTIONS
• INVERSION OF COUNTING DIRECTION
• SELF-TEST
• RADIUS/DIAMETER CONVERSION
• PRESETTING LOAD QUOTA
• MIDPOINT CALCULATION
• RESETTING/PRESETTING OF A DIMENSION
• SETTING LOAD QUOTA
• VARIABLE RESOLUTION
• MEMORY CLEARING
• MM/INCH CONVERSION MODE
• LINEAR CORRECTION
• ABS/INC COUNTING
• ANGULAR READING
• SCALE ZERO REF.
• RELAY OUTPUT ACTIVATION (opt.)
• DISABLING OF SCALE ZERO REF.
• SETTING OF RELAY QUOTA (opt.)
• COUNTING MODE
• SEXAGESIMAL DEGREES READING